When the refrigerant gas leaks during work, execute ventilation. If the resistance value is low, a disaster such as a leak or electric shock is caused at user’s If incorrect assembly or incorrect cable connection was done, a disaster such as a leak orĪfter the work has finished, be sure to use an insulation tester set (500V mugger) toĬheck the resistance is 2MW or more between the charge section and the non-charge Perform the work so that the cabinet or panel does not The refrigerant cannot be recovered in the outdoor unit otherwise a serious accident such as breakage or injury is caused.Īfter repair work, surely assemble the disassembled parts, and connect and lead the When the equipment is moved or repaired, be sure to recover the refrigerant with recovering device. Never recover the refrigerant into the outdoor unit. If the refrigerant gas leaks in the room, poisonous gas generates when gas touches to fire such as fan heater, stove or cocking stove though the refrigerant gas itself is innocuous. If air or others is mixed with the refrigerant, abnormal high pressure generates in the refrigerating cycle resulted in cause of injury due to breakage.Īfter installation work, check the refrigerant gas does not leak. When recharging the refrigerant in the refrigerating cycle, do not mix the refrigerant or air other than R410A into the specified refrigerant. Never charge the refrigerant over the specified amount.

Therefore if the refrigerant gas leaks, recover the refrigerant in the air conditioner, execute Refrigerant vacuuming, and then newly recharge the specified amount of liquid refrigerant. If charging refrigerant additionally when refrigerant gas leaks, the refrigerant composition in the refrigerating cycle changes resulted in change of air conditioner characteristics or refrigerant over the specified standard amount is charged and an abnormal high pressure is applied to the inside of the refrigerating cycle resulted in cause of breakage or injury. If different types of refrigerant are mixed, abnormal high pressure generates in the refrigerating cycle and an injury due to breakage may be caused. For an air conditioner which uses other refrigerant (R22, etc.), never use R410A. To prevent miss-charging, the route of the service port is changed from one of the former R22.įor an air conditioner which uses R410A, never use other refrigerant than R410A. When using it without ventilation, carbonģ) Do not bring inflammables close to the refrigerant cycle, otherwise fire of the welder may catch the inflammables.Ĭheck the used refrigerant name and use tools and materials of the parts which match with it.įor the products which use R410A refrigerant, the refrigerant name is indicated at a position on the outdoor unit where is easy to see. When using a gas stove, etc, be sure to put out fire before work otherwise the oil mixed with refrigerant gas may catch fire.Ģ) Do not use a welder in the closed room. When repairing the refrigerating cycle, take the following measures.ġ) Be attentive to fire around the cycle. Upward and then apply a water-cut method, otherwise a leak or production of fire is Please inform the users so that the third party (a child, etc.) does not approach the equipment.Ĭonnect the cut-off lead cables with crimp contact, etc, put the closed end side It causes an injury with tools or disassembled parts. The repair engineers close to the equipment. If unspecified parts are used, a fire or electric shock may be caused.īefore troubleshooting or repair work, do not bring a third party (a child, etc.) except It may cause a fire, electric shock or injury.įor spare parts, use those specified ( ).

If the earth wire is not correctly connected, contact an electric engineer for rework.ĭo not also disassemble or modify the parts. Terminals of the main unit, otherwise an electric shock is caused when a leak occurs.
#Pokemon lightning yellow e16.1 fix error connection manual#
Please read this Service Manual after understanding the described items thoroughly in the following contents, and keep them.īefore troubleshooting or repair work, check the earth wire is connected to the earth The important contents concerned to the safety are described on the product itself and on this Service Manual.